  velociti ? series mmi-6sf gamewell-fci 12 clintonville road, northford, ct 06472 - tel: (203) 484-7161 - fax: (203) 484-7118 specifications are for information only, are not intended for installation purposes, and are subject to change without notice. no responsibility is assumed by gamewell-fci for their use. ?2006 gamewell-fci. all rights reserved. www.gamewell.fci.com 9020-0633 rev. b page 1 of 2 description the velociti? series, multi-mod six zone interface module (mmi-6sf) provides six (6), style b (class b) or three (3), style d (class a) supervised initiat- ing device circuits (idc) suitable for use with u. l. listed conventional 2-wire smoke detectors as well as any normally open contact device. the velociti tm series use a communication proto- col that substantially in creases the speed of com- munication between the sensors and certain fci analog addressable fire alarm controls. these de- vices operate in a grouped fashion. if one of the devices in the group has a status change, the panel?s microprocessor stops the group poll and concentrates on the single device. the net effect is response speed up to five times greater than ear- lier designs. the mmi-6sf connects to the signaling line circuits (slc) of the fci analog addressable series fire alarm control panels. each of the mmi-6sf initiat- ing device circuits occupies its own address on the system?s slc allowing each to be fully programma- ble in its control-by-event sequence of operation. the address of the first in itiating device circuit is set with a pair of rotary dials. each remaining cir- cuit is automatically assigned to its own subse- quent address. the mmi-6sf module includes an address disable jumper matrix to allow a maximum of two unused addresses to be turned off to free these addresses for other purposes. an additional pair of jumpers selects either style b or style d circuit configurations. each circuit has its own status led that flashes to indicate proper polling and lights steadily when the output has been activated. velociti ? and e3 series ? are trademarks of fire control instruments. multi-mod six zone interface module features ? each mmi-6sf module provides six (6), style b (class b) or three (3), style d (class a) individually addressable individually programmable initiating device circuits. ? suitable for use with u. l. listed, compatible 2-wire conventional smoke sensors and normally open contact devices. ? removable wiring terminal blocks allow ease of installation and servicing terminal. ? blocks can accommodate 12 to 18 awg wire. ? flexible jumper configuration feature allowing one or two monitoring circuit addresses to be disabled. ? individual led indicators*. ? ideal for retrofit applications. ? as many as thirty-six (36), initiating device circuits in one 12? x 24? x 6.5? cabinet. ? two (2), mounting cabinets available for two (2), (mbb-2 cabinet) to six (6), (MBB-6 cabinet) units. ? bicolor leds flash green whenever the sensor is addressed, and light steady red on alarm.* note: *only the red led is operative in panels that do not oper- ate in velociti? mode. mmi-6sf an iso 9001-2000 company
specifications operating voltage: 15-32 vdc stand-by current: 2 ma alarm current: 40 ma (with all six leds lit) maximum idc wire resistance: 25 ohms temperature range: 32? f to 120 ? f (0 ? to 49 ? c) humidity: 10 to 85% (non-condensing) dimensions: 6.8? h x 5.8? w x 1.25? d (17.3 x 14.7 x 3.2 cm) mbb-2: 12.25? h x 9.25? w x 3.32? d (31.1 x 23.5 x 8.4 cm) MBB-6: 12.63? h x 24? w x 6.5? d (32.1 x 70.0 x 16.5 cm) dc voltage: 18-28 volts, power-limited ripple voltage: 0.1 volts rms maximum current: 90 ma per module external supply voltage gamewell-fci 12 clintonville road, northford, ct 06472 - tel: (203) 484-7161 - fax: (203) 484-7118 www.gamewell.fci.com 9020-0633 rev. b page 2 of 2 ordering information model description mmi-6sf multi-mod 6 zone interface module mbb-2 backbox, 2 unit MBB-6 backbox, 6 unit, requires mch-6 mch-6 6-unit mounting chassis description (continued) two (2), multi-mod series units can be mounted in one mbb-2 cabinet. additional mounting options include the mch-6 chassis that can accommodate six (6), multi-mod series modules. the mch-6 chas- sis can be installed in a custom cabinet or can be mounted in the MBB-6 cabinet allowing up to six (6), multi-mod series modules in one cabinet. the initiating device circuit of the mmi-6sf can sup- port a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. the mmi-6sf is ideal for applications where central- ized location of circuits is required. as many as sixty (60), initiating device circuits may be located in a cabinet that is only 12.63? h x 24? w x 6.5? d in di- mension, saving valuable wall space in mechanical rooms and electrical closets and reducing cost of installation.


▲Up To Search▲   

 
Price & Availability of MBB-6

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X